Research Article

Relative Contributions of Intracranial Pressure and Intraocular Pressure on Lamina Cribrosa Behavior

Table 4

LC peak strain in the trial runs of full factorial simulation experiment with porcine sclera material property.

LC peak strain (%)IOP (mmHg)
10152545

ICP (mmHg)51.922.553.816.33
101.832.453.696.17
151.792.383.576.02