Research Article

Changes in Corneal Volume at Different Areas and Its Correlation with Corneal Biomechanics after SMILE and FS-LASIK Surgery

Table 3

Correlation between the reduction of corneal volume and spherical equivalent with the change in corneal hysteresis and corneal resistance factor at 3 months.

ParametersSMILEFS-LASIK
r valuer value

△CV5 VS △CRF0.498<0.0010.3630.012
△CV5-10 VS△CRF0.2700.0580.1250.403
△CV5 VS △CH0.3740.0070.2640.073
△CV5-10 VS △CH0.1160.4200.0980.512
△CV5 VS △SE−0.746<0.0010.798<0.001
△CV5-10 VS △SE0.3530.0120.4400.002
△SE VS △CRF0.559<0.0010.598<0.001
△SE VS △CH0.506<0.0010.4720.001

CRF: corneal resistance factor,CH: corneal hysteresis, CV5: corneal volume of the central 5 mm diameter area, CV5-10: corneal volume of the peripheral 5–10 mm diameter area, SE: spherical equivalent, △: the reduction at postoperative month 3, (Pearson correlation).