Research Article

XEN Glaucoma Implant for the Management of Operated Uncontrolled Glaucoma: Results and Complications during a Long-Term Follow-Up

Table 2

Visual acuity (decimal notification) and interocular pressure mean values, median values, standard deviations, and range before and after surgery.

nMean (SD)MedianRangeMD (95% CI)

Visual acuity with the combined procedure (BCVA)
Preop100.2 (0.1)0.150.01 to 0.70.08 (0.02; 0.11)0.001
Final100.6 (0.22)0.550.3 to 1.00
Change100.4 (0.44)0.20.1 to 0.8

Visual acuity with the solo procedure (BCVA)
Preop590.35 (0.31)0.300.001 to 1.000.09 (0.04; 0.13)<0.001
Final490.41 (0.35)0.400.00 to 1.00
Change490.08 (0.16)0.01−0.30 to 0.60

Intraocular pressure (IOP)
Preop6824.82 (8.03)22.0017.00 to 45.00−7.48 (−10.04; −4.93)<0.001
Final6417.45 (5.84)17.007.00 to 38.00
Change64−7.48 (10.24)−5.00−36.00 to 21.00
Change (%)64−23.3% (32.5%)−24.2%−81.6% to 123.5%

SD: standard deviation; preop: preoperatively; MD: mean difference calculated as final value–preop value with 95% confidence interval; paired t-test; combined procedure: XEN implantation with phacoemulsification; solo procedure: XEN implantation.