Research Article

Clinical Outcomes of Aberration-Free All Surface Laser Ablation (ASLA) vs. Aberration-Free ASLA Assisted by Smart Pulse Technology in High Myopia: A One-Year Follow-Up Study

Table 1

Baseline preoperative valuesa.

Baseline preoperative valuesSPT groupNon-SPT group

Number of eyes5385
Mean age (years)26.25 ± 5.6424.62 ± 4.910.082
Mean preoperative logMAR UDVA1.294 ± 0.2451.280 ± 0.2690.725
Mean preoperative logMAR CDVA−0.007 ± 0.017−0.024 ± 0.0340.02b
Mean preoperative refractive errors (D)
Sphere−7.60 ± 1.31−7.60 ± 1.060.925
Cylinder−0.83 ± 0.64−1.00 ± 0.710.206
Spherical equivalent−8.02 ± 1.32−8.10 ± 1.050.507
Optical zone diameter (mm)6.12 ± 0.266.18 ± 0.260.494
Treatment diameter (mm)7.91 ± 0.338.09 ± 0.330.001b
Ablation depth (μm)160.85 ± 13.05171.49 ± 11.25<0.001b
Residual stromal bed thickness (μm)345.83 ± 21.44330.11 ± 18.71<0.001b

SPT = smart pulse technology; UDVA = uncorrected distance visual acuity; CDVA = corrected distance visual acuity. aValues are presented as mean ± standard deviation. bSignificant difference between the SPT and non-SPT groups (Student’s t-test/Mann–Whitney U-test).