Research Article
Evaluation of Intraocular Lens Tilt and Decentration in Congenital Ectopia Lentis by the Pentacam Scheimpflug System
Table 2
IOL position parameters of CEL patients according to axial length.
| | Total | AL < 24 mm | 24 mm ≤ AL < 26 mm | AL ≥ 26 mm | P value |
| Tilt (degree) |
| Temporally | 2.21 ± 1.53 | 2.22 ± 1.46 | 2.38 ± 1.64 | 2.19 ± 1.58 | 0.963 | Nasally | −1.84 ± 2.04 | −1.56 ± 1.52 | −1.39 ± 1.27 | −1.83 ± 1.66 | 0.897 | Superiorly | 2.22 ± 2.18 | 1.34 ± 1.77 | 1.89 ± 2.00 | 3.50 ± 2.71 | 0.031 | Inferiorly | −1.70 ± 1.62 | −1.19 ± 1.63 | −1.65 ± 1.72 | −1.88 ± 1.65 | 0.523 |
| Decentration (mm) |
| Temporally | 0.49 ± 0.38 | 0.46 ± 0.25 | 0.38 ± 0.39 | 0.52 ± 0.41 | 0.795 | Nasally | −0.69 ± 0.46 | −0.53 ± 0.27 | −0.74 ± 0.37 | −0.56 ± 0.19 | 0.194 | Superiorly | 0.72 ± 0.58 | 0.46 ± 0.25 | 0.48 ± 0.22 | 0.72 ± 0.28 | 0.045 | Inferiorly | −0.68 ± 0.54 | −0.44 ± 0.26 | −0.44 ± 0.46 | −0.94 ± 0.56 | 0.033 |
|
|