Research Article

Corneal Astigmatism Alteration after Combined Silicone Oil Removal and Cataract Surgery with Intraocular Lens Implantation

Table 2

Comparison of corneal astigmatism status in the baseline and postoperative visit.

ParametersTimeMean ± SDMD value95% CI for difference
Lower boundUpper bound

K1Pre-op43.20 ± 1.44
3 D-post-op42.76 ± 1.710.4420.0160.0700.813
1 W-post-op42.84 ± 1.600.3600.0090.0780.641
1 M-post-op42.95 ± 1.520.2500.0350.0150.484

K2Pre-op44.22 ± 1.39
3 D-post-op44.69 ± 1.75−0.4690.002−0.772−0.167
1 W-post-op44.60 ± 1.67−0.380<0.001−0.610−0.150
1 M-post-op44.54 ± 1.62−0.3160.001−0.512−0.119

Corneal astigmatismPre-op−1.02 ± 0.57
3 D-post-op−1.93 ± 1.390.911<0.0010.4651.358
1 W-post-op−1.76 ± 1.220.739<0.0010.3611.118
1 M-post-op−1.58 ± 1.050.565<0.0010.2470.883

D, day; W, week; M, month; post-op, postoperation; SD, standard deviation; MD, mean difference; CI, confidence interval. .