Research Article
Study on Effect of Number of Transparent Covers and Refractive Index on Performance of Solar Water Heater
Table 1
Specification of flat plate collector.
| Description | Specification |
| Collector dimension (Length × Width) | 1.6 m × 1.1 m | Collector type | Flat plate | Absorber dimension (Length × Width) | 1.5 m × 1.0 m | Plate to cover spacing | 2.5 cm | Spacing between covers | 2.5 cm | Thermal conductivity of plate |
35 W/m-°C | Plate thickness | 2 mm | Cover thickness | 2 mm | Plate absorptivity/emissivity | 0.95 | Outer diameter of lateral tube | 18 mm | Inner diameter of lateral tube | 14 mm | Tube center to center distance | 12 cm | Glass cover absorptivity/emissivity | 0.88 | K | 0.0524 per plate | Adhesive resistance | Negligible | Fluid to tube heat transfer coefficient | 205 W/m2-°C | Water flow rate | 70 kg/hr | Inlet water temperature | 60°C | Ambient temperature | 25°C | Wind speed | 3.1 m/s | Back insulation thickness | 5 cm | Insulation thermal conductivity | 0.04 W/m-°C | Side loss coefficient | 10 percent of bottom loss | Collector tilt | Latitude (12.916) | Surface Azimuth angle | 0° | Date | January 21st | For January 21st , , value | 610 W/m2, 0.00, 0.242 | Location of flat plate collector | VIT University (12.96°N, 79.15°E) |
|
|