Research Article
Model-Based Control Design of Series Resonant Converter Based on the Discrete Time Domain Modelling Approach for DC Wind Turbine
Table 2
Specifications of digital controller.
| Switching frequency | 1.0k (Hz) (full load) |
| Interrupt frequency of digital controller (i.e. ) | 2.0k (Hz) (full load) |
| Q-factor | 1.0 |
| Phase margin | 52° |
| Power reference signal | 10MW (full load) |
| Sampling rate of A/D conversion | 1M (Hz) |
| Duty cycle | 50% |
|
|