Research Article
A Fast and Accurate Analytical Method for Parameter Determination of a Photovoltaic System Based on Manufacturer’s Data
Table 6
A summary of appropriate parameters for MSX60, BP-SX 150, KC200GT, and BP3235T.
| | MSX60 | BP-SX 150 | KC200GT | BP3235T | Method 1 | Method 2 | Method 1 | Method 2 | Method 1 | Method 2 | Method 1 | Method 2 |
| Rs (Ω) | 0.150 | 0.150 | 0.3301 | 0.3301 | 0.2188 | 0.2188 | 0.2420 | 0.2420 | Rsh (Ω) | 1148.49 | 8273.5533 | 3866.64 | 22158.12 | 1028.695 | 679.35 | 1066.37 | 1066.30 | A | 1.7 | 1.737 | 1.96 | 2.007 | 1.809 | 1.882 | 1.7920 | 1.8626 | Io (A) | 5.6096E − 6 | 7.4668E − 06 | 2.9076E − 5 | 3.8513E − 5 | 1.6535E − 5 | 2.7501E − 5 | 1.1942E − 5 | 1.99E − 5 | Iph (A) | 3.800013 | 3.8001 | 4.7504 | 4.7501 | 8.2119 | 8.2127 | 8.481938 | 8.4819 |
|
|