Research Article
Design and Development of a Low-Cost, Portable Monitoring Device for Indoor Environment Quality
Table 3
IEQ index with parameters.
| | IEQ parameter | Ambient levels | Health risk levels |
| | Humidity | 40–70% | 70 > H > 40% | | Temperature | 16–24°C | 24 > T > 16°C | | PM2.5 | <35 μg/m3 | >35 μg/m3 | | PM10 | <150 μg/m3 | >150 μg/m3 | | Total VOC | 50–325 ppb | >500 ppb | | CO2 | 350–1000 ppm | >5000 ppm | | CO | 0–10 ppm | >10 ppm | | Illuminance | 200–500 lux | <100 lux | | Sound levels | 0–70 dB | >80 dB |
|
|