Research Article
Useful Piezoelectric Sensor to Detect False Liquor in Samples with Different Degrees of Adulteration
Table 1
Results of
for four independent tests (average ± SD). Each test contains one hundred measures.
| Methanol (%) | Test 1 (Hz) | Test 2 (Hz) | Test 3 (Hz) | Test 4 (Hz) | Average | SD | Average | SD | Average | SD | Average | SD |
| 0% | 1374.6 | 27.87 | 1462.3 | 31.71 | 1364.6 | 29.51 | 1260.9 | 26.56 | 10% | 1273.0 | 30.60 | 1368.7 | 33.95 | 1284.8 | 20.82 | 1187.3 | 18.06 | 25% | 1120.7 | 15.72 | 1228.3 | 32.55 | 1165.1 | 104.91 | 1076.9 | 15.96 | 35% | 1019.1 | 33.00 | 1134.8 | 24.98 | 1085.3 | 54.89 | 1003.3 | 34.06 | 50% | 866.7 | 69.61 | 994.4 | 40.35 | 965.7 | 19.91 | 892.9 | 21.23 | 55% | 815.9 | 12.94 | 947.6 | 21.22 | 925.8 | 15.86 | 856.1 | 19.26 | 65% | 714.3 | 20.50 | 854.0 | 18.65 | 846.0 | 46.25 | 782.4 | 16.47 | 75% | 612.8 | 10.10 | 760.4 | 14.45 | 766.2 | 21.06 | 708.8 | 41.42 |
|
|