Research Article
Suppression Method of Jump Points for Multipole Magnetic Encoder at Low Temperature Based on Single-Pole Angle Value Fitting
Table 1
Without the method proposed in this paper.
| Temperature point | Jump points occur with forward rotation | Jump points occur with reverse rotation | Rotor speed |
| 25°C | 0 | 0 | 25°/s | -10°C (cool down) | 2 | 3 | 25°/s | -20°C (cool down) | 4 | 4 | 25°/s | -40°C (cool down) | 5 | 5 | 25°/s | -20°C (warming up) | 3 | 4 | 25°/s | -10°C (warming up) | 2 | 2 | 25°/s | 25°C (warming up) | 0 | 0 | 25°/s |
|
|