Research Article
Spot-Centroid Determination Algorithms in Semiactive Laser Photodiodes for Artillery Applications
Table 2
Correlations between ideal and calculated radial components.
| Spot-detector ratio | | 0.1 | 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | 0.8 | 0.9 | 1.0 |
| 0.25 | | 0.50 | 0.89 | — | — | — | — | — | — | — | — | 0.25 | | 1.09 | 2.89 | — | — | — | — | — | — | — | — | 0.25 | | 0.70 | 1.27 | — | — | — | — | — | — | — | — | 0.25 | | 1.54 | 4.09 | — | — | — | — | — | — | — | — | 0.50 | | 0.25 | 0.50 | 0.72 | 0.90 | 1.00 | — | — | — | — | — | 0.50 | | 0.52 | 1.09 | 1.80 | 2.90 | 7.74 | — | — | — | — | — | 0.50 | | 0.36 | 0.70 | 1.01 | 1.27 | 1.41 | — | — | — | — | — | 0.50 | | 0.73 | 1.54 | 2.54 | 4.10 | 10.95 | — | — | — | — | — | 0.75 | | 0.17 | 0.34 | 0.49 | 0.61 | 0.74 | 0.86 | 0.97 | — | — | — | 0.75 | | 0.34 | 0.70 | 1.06 | 1.42 | 1.89 | 2.60 | 4.16 | — | — | — | 0.75 | | 0.24 | 0.47 | 0.69 | 0.87 | 1.04 | 1.22 | 1.37 | — | — | — | 0.75 | | 0.48 | 0.99 | 1.50 | 2.01 | 2.67 | 3.68 | 5.88 | — | — | — | 1.00 | | 0.07 | 0.14 | 0.23 | 0.32 | 0.43 | 0.54 | 0.67 | 0.79 | 0.92 | — | 1.00 | | 0.14 | 0.29 | 0.47 | 0.67 | 0.92 | 1.22 | 1.61 | 2.16 | 3.14 | — | 1.00 | | 0.10 | 0.20 | 0.32 | 0.46 | 0.61 | 0.77 | 0.94 | 1.12 | 1.30 | — | 1.00 | | 0.19 | 0.41 | 0.66 | 0.95 | 1.30 | 1.72 | 2.27 | 3.06 | 4.43 | — |
|
|