Research Article

A Nonlinear Calibration Method Based on Sinusoidal Excitation and DFT Transformation for High-Precision Power Analyzers

Table 1

Voltage measurement comparison.

AC voltage (V) signal frequency 100 Hz
Standard valueThe old methodThe proposed method
Phase APhase BPhase CPhase APhase BPhase C

30.0030.0129.9829.9730.0029.9629.95
60.0059.9659.9860.0260.0559.9859.94
100.00100.02100.04100.01100.0899.9699.96
220.00220.11220.13220.05220.16219.92219.90
380.00379.90380.28379.86380.24379.88379.85
500.00500.04499.77499.85500.31500.47499.97
660.00660.39660.56659.67660.67659.64659.78
800.00801.18801.28800.79800.85800.83799.69
950.00950.95951.58950.62951.52949.50948.89