Research Article
A Nonlinear Calibration Method Based on Sinusoidal Excitation and DFT Transformation for High-Precision Power Analyzers
Table 1
Voltage measurement comparison.
| AC voltage (V) signal frequency 100 Hz | Standard value | The old method | The proposed method | Phase A | Phase B | Phase C | Phase A | Phase B | Phase C |
| 30.00 | 30.01 | 29.98 | 29.97 | 30.00 | 29.96 | 29.95 | 60.00 | 59.96 | 59.98 | 60.02 | 60.05 | 59.98 | 59.94 | 100.00 | 100.02 | 100.04 | 100.01 | 100.08 | 99.96 | 99.96 | 220.00 | 220.11 | 220.13 | 220.05 | 220.16 | 219.92 | 219.90 | 380.00 | 379.90 | 380.28 | 379.86 | 380.24 | 379.88 | 379.85 | 500.00 | 500.04 | 499.77 | 499.85 | 500.31 | 500.47 | 499.97 | 660.00 | 660.39 | 660.56 | 659.67 | 660.67 | 659.64 | 659.78 | 800.00 | 801.18 | 801.28 | 800.79 | 800.85 | 800.83 | 799.69 | 950.00 | 950.95 | 951.58 | 950.62 | 951.52 | 949.50 | 948.89 |
|
|