Table 2

100 Hz current measurement comparison.

AC current (A) signal frequency 100 Hz
Standard valueThe old methodThe proposed method
Phase APhase BPhase CPhase APhase BPhase C

0.100.100.100.100.100.100.10
0.500.490.500.490.490.490.49
1.000.990.990.990.980.990.98
5.005.004.995.004.974.984.99
10.0010.049.9810.019.999.9810.01
25.0025.0924.8125.1124.9024.9824.94
40.0038.9839.0138.6439.8540.0439.96
55.0052.1851.9552.0254.2454.4354.32