Research Article

A Nonlinear Calibration Method Based on Sinusoidal Excitation and DFT Transformation for High-Precision Power Analyzers

Table 4

1000 Hz current measurement comparison.

AC current (A) signal frequency 1000 Hz
Standard valueThe old methodThe proposed method
Phase APhase BPhase CPhase APhase BPhase C

0.100.100.100.100.100.100.10
0.500.490.500.490.490.490.49
1.000.990.990.990.990.990.98
5.005.014.975.004.984.974.99
10.0010.119.889.869.999.9810.01
25.0024.7224.6825.1824.9224.9424.91
40.0038.6239.2838.4639.7940.0839.89
55.0051.7851.6551.7154.2454.3154.29