Research Article
Research on the Three-Dimensional Power Frequency Electric Field Measurement System
Table 2
Fitting results of measured values of each sensor unit.
| Unit number | Inherent capacitance Cd (pF) | Linearity | Sensitivity () |
| 1 | 3.01 | 1.81% | 0.216 | 2 | 5.79 | 2.88% | 0.241 | 3 | 9.12 | 3.09% | 0.241 | 4 | 13.02 | 1.60% | 0.248 | 5 | 17.84 | 1.61% | 0.116 | 6 | 22.88 | 1.64% | 0.121 |
|
|