Research Article

Research on the Three-Dimensional Power Frequency Electric Field Measurement System

Table 4

Linear relationship between the voltage value output by the electric field sensor and the uniform electric field.

SensorLinear relationshipSensitivity coefficient, Degree of fit

Sensor 119.1180.9998
Sensor 219.1380.9997
Sensor 319.1080.9998
Sensor 419.0640.9995
Sensor 519.1360.9998
Sensor 619.0440.9996
Average value—19.1010.9997
Mean absolute deviation—0.0315560.0001