Research of Magnetic Shielding on the Closing Gap of Optical Fiber Current Sensor

Figure 11

Variations of the magnetic induction intensity inside the magnetic ring. The length, thickness, and inner diameter of the magnetic ring were 50, 2, and 13 mm, respectively: (a) axial direction and (b) radial direction.