Summary of applied tests.

Test numberExcitation typeLT positionSimulated damage

11 HzPosition 1No
27.4 HzPosition 1No
323 HzPosition 1No
41-10 Hz sweepPosition 1No
55-50 Hz sweepPosition 1No
6White noisePosition 1No
7ShockPosition 1No
81 HzPosition 2No
97.4 HzPosition 2No
1023 HzPosition 2No
111-10 Hz sweepPosition 2No
125-50 Hz sweepPosition 2No
13White noisePosition 2No
1423 HzPosition 2No
15White noisePosition 2No
16White noisePosition 2Center north
17White noisePosition 2Shaker south
1823 HzPosition 2Shaker south

LT: laser tracker.