Defect size and size quantization error before and after weighted full-focus imaging.

Defects in the serial numberPCITF-PCF
Transverse dimensionsLongitudinal dimensionTransverse dimensionsLongitudinal dimension

13.21.01.70.9
23.51.21.81.1
33.31.02.11.0
43.11.11.80.9
53.01.42.01.2
63.31.41.81.3
72.61.51.81.3
82.51.51.71.3
92.31.31.81.3
101.71.41.61.4
111.51.31.31.3
121.51.31.31.2
131.51.21.31.2
141.61.1
151.31.1
16
17
18
Mean size (2~13)2.481.31.691.2
Dimensional quantization error