Research Article
Weighted Full-Focus Defect Detection and Imaging Method Based on Threshold Fusion for Phase Coherence Factor
Table 4
Defect size and size quantization error before and after weighted full-focus imaging.
| Defects in the serial number | PCI | TF-PCF | Transverse dimensions | Longitudinal dimension | Transverse dimensions | Longitudinal dimension |
| 1 | 3.2 | 1.0 | 1.7 | 0.9 | 2 | 3.5 | 1.2 | 1.8 | 1.1 | 3 | 3.3 | 1.0 | 2.1 | 1.0 | 4 | 3.1 | 1.1 | 1.8 | 0.9 | 5 | 3.0 | 1.4 | 2.0 | 1.2 | 6 | 3.3 | 1.4 | 1.8 | 1.3 | 7 | 2.6 | 1.5 | 1.8 | 1.3 | 8 | 2.5 | 1.5 | 1.7 | 1.3 | 9 | 2.3 | 1.3 | 1.8 | 1.3 | 10 | 1.7 | 1.4 | 1.6 | 1.4 | 11 | 1.5 | 1.3 | 1.3 | 1.3 | 12 | 1.5 | 1.3 | 1.3 | 1.2 | 13 | 1.5 | 1.2 | 1.3 | 1.2 | 14 | 1.6 | 1.1 | | | 15 | 1.3 | 1.1 | | | 16 | | | | | 17 | | | | | 18 | | | | | Mean size (2~13) | 2.48 | 1.3 | 1.69 | 1.2 | Dimensional quantization error | | | | |
|
|