Research Article

Study on Impact Test System of Manipulator Based on Six Axis Force Sensor and Intelligent Controller

Table 3

Results of mechanical arm impact test.

Serial numberDetection force/NComponent force in three directions/NCollision position/mmCapacity of calculation/NCalculation position/mmForce absolute error/NRelative error of force/%Position absolute error/mmRelative position error/%

1-45.01116.79-46.36122.101.350.885.314.83
100-62.8669.72-62.2376.490.630.886.774.83
63.41298.7164.45302.471.030.883.764.83
62.35060.381.351.972.381.351.78
210073.9538.4972.7537.641.202.380.851.78
25.38167.0324.31167.901.072.380.871.78
72.19213.4170.71226.901.480.5813.417.78
310030.16124.0829.67135.710.490.5811.637.78
-62.28486.49-63.28503.800.990.5817.317.78
76.964.0778.76261.181.810.762.652.85
410014.6936.8316.42261.181.730.762.162.85
-62.22264.19-61.65261.180.560.763.012.85
92.6840.0394.5640.462.262.200.431.55
510010.3509.670.040.672.200.041.55
36.08148.0337.55149.931.472.201.901.55
-82.9448.63-84.1947.321.251.950.492.39
610048.67049.612.380.931.952.382.39
-27.41184.16-29.0585.841.641.951.682.39