Research Article
Simple Pressure Sensor with Highly Customizable Sensitivity Based on Fiber Bragg Grating and Pill-Shaped 3D-Printed Structure
Table 1
Comparison of the sensitivity of several reported FBG pressure sensors.
| Method | Pressure range | Sensitivity (wavelength shift) | References |
| Bare FBGs were put in the pressure chamber | 70 MPa | nm/MPa | [4] | FBGs were put in a glass-bubble housing | 14 MPa | nm/MPa | [5] | FBGs were glued on Bourdon tube | 1 MPa | 1.414 nm/MPa | [6] | FBGs were put in a resin cylinder | 0.4 MPa | 2.08 nm/MPa | [18] | FBGs based on the diaphragm-cantilever | 10 MPa | 0.34 nm/MPa | [26] | FBGs based on the plane diaphragm | 50 MPa | nm/MPa | [27] | FBGs based fixed guided beam | 2 MPa | 1.03 nm/MPa | [28] | FBG encapsulated in a partially polymer-filled metal cylinder | 0.1 MPa | 39.6 nm/MPa | [10] | FBG embedded in a polymer-filled metal cylinder | 0.45 MPa | 5.277 nm/MPa | [12] | FBG encapsulated in a polymer-half-filled metal cylinder | 0.2 MPa | 33.5 nm/MPa | [13] | FBGs were put in the pill-shaped 3D-printed structure | 0.35 MPa | 4.11 nm/MPa | This study |
|
|