Research Article

Field Validation of a Public Health Particulate Matter (PHPM) Low-Cost PM2.5 Monitor and Commercial Sensors with Light Scattering Technology

Table 1

Characteristics of SI, SN, and SV type dust measuring instruments used in research.

CharacteristicsInstrument type
SISNSV

Approximate price (US dollars)66.65050
Packaging size (mm)
Product weight (g)2519386
Estimated PMx concentrationPM2.5PM2.5PM2.5
Measurement of PM2.5 concentration
 (i) Measuring range (μg/m3)0-9990-500
 (ii) Resolution (μg/m3)11
 (iii) Accuracy (μg/m3)±15%, 10
Measurement methodLaser scatteringLaser scatteringPLANTOWER laser particulate matter sensor
Display
Limitation(i) Cannot be used in environments with high concentrations of PM2.5 or greater than 999 μg/m3(i) Uses medical grade low current laser transmitter(i) Cannot be used in environments with high concentrations of PM2.5 or greater than 500 μg/m3
(ii) Cannot be used in an environment with too high temperatures(ii) Uses temperature and humidity compensation algorithm which ensures the accuracy of product testing(ii) Cannot be used in an environment with too high temperatures
(iii) Cannot be used in a humid environment(iii) Uses a special air duct design by air intake every 30 seconds is 283 mL(iii) Cannot be used in an environment with too high temperatures
(iv) Use heat dissipation design which ensures that the laser transmitter 3000 h(iv) Cannot be used in a humid environment
(v) Cannot be used in an environment with excessive temperature