Field Validation of a Public Health Particulate Matter (PHPM) Low-Cost PM2.5 Monitor and Commercial Sensors with Light Scattering Technology
Table 2
Characteristics of SC, CKDPM, and PHPM type dust measuring instruments used in research.
Characteristics
Instrument type
SC
CKDPM
PHPM
Approximate price (US dollars)
23.3
66.6
23.0
Packaging size (mm)
Product weight (g)
86
180
150
Estimated PMx concentration
PM2.5
PM2.5, PM10, PM1
PM2.5
Measurement of PM2.5 concentration
(i) Measuring range (μg/m3)
—
0-500
0-500
(ii) Resolution (μg/m3)
—
1
1
(iii) Accuracy (μg/m3)
—
Measurement method
—
Laser scattering
Laser scattering
Display
LED digital display
LED digital display
LED digital display
Limitation
(i) Cannot be used in an environment with too high temperatures
(i) Cannot be used in environments with high concentrations of PM2.5 or greater than 500 μg/m3
(i) Cannot be used in environments with high concentrations of PM2.5 or greater than 500 μg/m3
(ii) Cannot be used in a humid environment
(ii) Cannot be used in an environment with too high temperature
(ii) Cannot be used in an environment with too high temperature
(iii) Cannot be used in a humid environment
(iii) Cannot be used in a humid environment
Note: CKDPM type dust detector is a dust meter supported by the Chronic Kidney Disease Prevention and Slowing Project in the Northeast (CKDNET) sampler.