Research Article
Intelligent Optimization of Parameters for Tens of MA-Class Z-Pinch Accelerators
Table 6
Simulation results with different inner diameters of the LTD cavity for a 40 MA target peak load current.
| D inner (m) | n b | max (nc) | n c | n m | min (nb × nc × nm) | Z in (Ω) | Z out (Ω) | r waterflare (m) | T line (ns) | L center (nH) | U stack (MV) | I max (MA) | η (%) |
| 0.8 | 21 | 23 | 19 | 142 | 56658 | 0.016 | 0.216 | 3.0 | 595 | 16.91 | 7.77 | 40.0 | 18.8 | 0.91 | 23 | 29 | 29 | 78 | 52026 | 0.039 | 0.212 | 3.0 | 385 | 16.47 | 7.51 | 40.1 | 20.5 | 1.0 | 25 | 34 | 34 | 58 | 49300 | 0.057 | 0.214 | 2.96 | 311 | 16.48 | 7.44 | 40.0 | 21.8 | 1.1 | 27 | 40 | 38 | 46 | 47196 | 0.075 | 0.214 | 2.98 | 353 | 16.48 | 7.41 | 40.0 | 22.7 |
|
|