Research Article

Simulation of the Compression Testing of Additively Manufactured Lattice Structures Using Inputs from Microcomputed Tomography

Table 1

CT scan measurements of lattice structures including cylindrical diameters, strut thickness, node thickness, internal porosity, and [25].

ParameterAs-designedP280-T30P280-T60P280-T90P210-T30P360-T30

Cylindrical diameter (μm)420396403381348447
Strut thickness (μm)420363357344326386
Node thickness (μm)420447463431399504
Internal porosity (%)02.170.2710.80.25
(μm)01722212125