Research Article

Real-Time Application Optimization Control Algorithm for Energy Management Strategy of the Hybrid Power System Based on Artificial Intelligence

Table 4

Fuel consumption results of CD/CS strategy, dynamic planning strategy, and fast energy management strategy.

Energy management strategyEquivalence factorTerminal SOC (%)Fuel consumption (kg)

CD/CS strategy3.5530.260.7165
Fast energy management3.0229.960.6847
Dynamic programming2.7830.900.6968