Research Article

Tundish Cover Flux Thickness Measurement Method and Instrumentation Based on Computer Vision in Continuous Casting Tundish

Table 4

Measurement results and comparison between our method and the traditional single/double wire measurement methods. All these data were obtained from Sanming Steel Plant.

TCF thickness measured by our method (mm)TCF thickness measured by single-wire measurement method from operator no. 1 (mm)TCF thickness measured by double-wire measurement method from operator no. 2 (mm)Deviation of our method from single-wire measurement method (mm)Deviation of our method from double-wire measurement method (mm)

26.123.924.82.21.3
24.823.323.51.51.3
20.718.822.11.9−1.4
30.526.127.64.42.9
29.124.627.64.51.5
24.922.826.12.1−1.2
22.821.824.11−1.3
29.825.128.34.71.5
28.622.927.35.71.3
25.722.526.13.2−0.4
20.523.625.3−3.1−4.8
32.928.830.84.12.1
29.825.326.24.53.6
24.321.827.52.5−3.2
20.918.526.52.4−5.6
20.823.925.8−3.1−5
35.131.828.83.36.3
31.633.426.9−1.84.7
29.128.426.60.72.5
21.024.425.8−3.4−4.8

Biggest deviation5.76.3
Mean deviation3.02.8