Measurement results and comparison between our method and the traditional single/double wire measurement methods. All these data were obtained from the Nanjing Steel Plant.

TCF thickness measured by our method (mm)TCF thickness measured by single-wire measurement method from operator no. 1 (mm)TCF thickness measured by double-wire measurement method from operator no. 2 (mm)Deviation of our method from single-wire measurement method (mm)Deviation of our method from double-wire measurement method (mm)

33.535.833.6−2.3−0.1
31.031.930.7−0.90.3
30.027.629.82.40.2
37.640.336.1−2.71.5
35.739.533.1−3.82.6
31.230.028.51.22.7
26.529.123.8−2.62.7
40.040.937.6−0.92.4
37.931.534.86.43.1
31.027.629.73.41.3
21.625.928.1−4.3−6.5
43.842.938.10.95.7
38.538.734.6−0.23.9
28.931.630.8−2.7−1.9
25.324.328.51−3.2
45.545.842.5−0.33
40.642.633.0−27.6
37.137.132.105

Biggest deviation6.47.6
Mean deviation2.13.0