Research Article
A New Wavelet Threshold Function and Denoising Application
Table 1
Result of SNR and MSE after Heavy sine’s denoising.
| | Hard threshold | Soft threshold | Garrote threshold | New threshold |
| SNR | 29.5306 | 27.4918 | 30.7351 | 31.2172 | MSE | 0.2032 | 0.3249 | 0.1539 | 0.1378 |
|
|