Research Article
An Energy Efficiency Evaluation Method Based on Energy Baseline for Chemical Industry
Table 2
Energy performance related variables and parts of measured data.
| Name | Number | Unit | Data (per minute) | 10:00 | 10:01 | 10:02 | 10:03 | 10:04 | 10:05 | ⋯ |
| The compressor speed | | RPM | 4078 | 4067 | 4025 | 4070 | 4059 | 4012 | ⋯ | K-13001 inlet pressure | | KPA | 33.3 | 32.8 | 32.9 | 33.2 | 33.0 | 33.2 | ⋯ | K-13001 outlet temperature | | °C | 35.0 | 34.9 | 35.4 | 35.4 | 35.3 | 35.2 | ⋯ | K-13004 outlet pressure | | °C | 75.2 | 74.8 | 73.9 | 75.2 | 74.9 | 74.7 | ⋯ | K-13004 outlet pressure | | MPA | 1.555 | 1.549 | 1.540 | 1.547 | 1.548 | 1.549 | ⋯ | K-13004 outlet flow | | T/H | 241.9 | 241.9 | 242.7 | 245.2 | 243.2 | 241.4 | ⋯ | K-13005 outlet temperature | | °C | 70.9 | 71.8 | 70.8 | 71.3 | 70.8 | 71.2 | ⋯ | K-13005 outlet pressure | | MPA | 3.593 | 3.634 | 3.660 | 3.654 | 3.639 | 3.638 | ⋯ | Turbine inlet pressure | | MPA | 11.48 | 11.59 | 11.58 | 11.54 | 11.65 | 11.56 | ⋯ | Turbine inlet temperature | | °C | 518.2 | 515.9 | 515.5 | 514.8 | 513.5 | 515.0 | ⋯ | C-1365 tower top temperature | | °C | −21.5 | −21.9 | −21.6 | −21.5 | −21.7 | −21.8 | ⋯ | C-1365 tower top pressure | | MPA | 1.461 | 1.440 | 1.451 | 1.458 | 1.463 | 1.442 | ⋯ | K-1300 three return one | | % | 7.1 | 7.2 | 7.1 | 7.2 | 7.1 | 7.2 | ⋯ | K-1300 four return four | | % | 6.5 | 6.5 | 6.4 | 6.4 | 6.5 | 6.5 | ⋯ | K-1300 five return five | | % | 6.6 | 6.6 | 6.6 | 6.6 | 6.6 | 6.5 | ⋯ | K-13005 outlet flow | | T/H | 223.7 | 223.8 | 223.1 | 222.8 | 226.5 | 226.5 | ⋯ | Turbine outlet flow | | T/H | 323.1 | 322.8 | 320.0 | 324.0 | 323.5 | 322.3 | ⋯ | EnPI (/) | | — | 1.444 | 1.442 | 1.434 | 1.454 | 1.428 | 1.423 | ⋯ |
|
|