Energy performance related variables and parts of measured data.

NameNumberUnitData (per minute)
10:0010:0110:0210:0310:0410:05

The compressor speedRPM407840674025407040594012
K-13001 inlet pressureKPA33.332.832.933.233.033.2
K-13001 outlet temperature°C35.034.935.435.435.335.2
K-13004 outlet pressure°C75.274.873.975.274.974.7
K-13004 outlet pressureMPA1.5551.5491.5401.5471.5481.549
K-13004 outlet flowT/H241.9241.9242.7245.2243.2241.4
K-13005 outlet temperature°C70.971.870.871.370.871.2
K-13005 outlet pressureMPA3.5933.6343.6603.6543.6393.638
Turbine inlet pressureMPA11.4811.5911.5811.5411.6511.56
Turbine inlet temperature°C518.2515.9515.5514.8513.5515.0
C-1365 tower top temperature°C−21.5−21.9−21.6−21.5−21.7−21.8
C-1365 tower top pressureMPA1.4611.4401.4511.4581.4631.442
K-1300 three return one%7.17.27.17.27.17.2
K-1300 four return four%6.56.56.46.46.56.5
K-1300 five return five%6.66.66.66.66.66.5
K-13005 outlet flowT/H223.7223.8223.1222.8226.5226.5
Turbine outlet flowT/H323.1322.8320.0324.0323.5322.3
EnPI (/)1.4441.4421.4341.4541.4281.423