Research Article

Postbuckling and Free Nonlinear Vibration of Microbeams Based on Nonlinear Elastic Foundation

Table 1

Comparison of the present frequency with the exact frequency of P-P microbeam ().

l/hKLKPKNLPωexactωpresentR. error (%)

0.10.25101010513.604913.60460.0026
0.5101010516.413116.41280.0018
0.75101010520.245620.24540.0012
1.0101010524.628824.62860.0008

10.255050502022.755522.71850.1626
0.55050502024.538424.56360.1418
0.755050502027.251727.21980.1169
1.05050502030.649230.62040.0937