Research Article

A Linear-Correction Algorithm for Quasi-Synchronous DFT

Table 2

The required time (s) for the four harmonic-analysis algorithms for different numbers of iterations.

HanningQSDFTVFPLCQS

40.0018260.0011390.0106940.001844
50.0023880.0014400.0131800.002208
60.0026840.0017290.0157210.002438
70.0031190.0019790.0174950.002757
80.0035190.0022180.0200510.002998