Research Article

A Reliable Leakage Reduction Technique for Approximate Full Adder with Reduced Ground Bounce Noise

Table 1

Comparison of leakage power dissipation (pW) between existing and modified FA at 1.1v, 27°C temp.

DataConv_adderMA1MA2MA3MA4Imprecise_adder_1Imprecise_adder_2Hybrid_FAInexact_adder_2017MAA1MAA2MAA3MAA4

000119.78170.7696360.0111169.355.2062.446.840.943.3

001140.410769.6676161.0126161.449.7059.044.036.634.5

010150.07773.2707366.2143161.464.2041.439.227.340.6

011211.09389.4878968.5150167.6903.237.638.128.033.3

100192.88382.0889157.4128164.22426.253.738.739.244.0

101184.09883.71027168.5157165.649.7849.533.540.132.8

110191.49687.88710165.8176253964.2736.930.228.041.0

111248.511890.410410569.4205156072.9336.326.628.534.0

Avg.179.79480.8848265149.563646147.137.133.638