Research Article
Speed Control of PMSM Based on an Optimized ADRC Controller
Table 2
Comparison between Traditional ADRC and Optimized ADRC.
| ADRC | Input signal | Overshoot(%) | Adjustment time(s) |
| Traditional ADRC | Unit step | 9.76 | 0.39 | Sinusoidal | / | 0.71 | Small disturbance | 17.91 | 1.89 | Big disturbance | 259.34 | 2.01 | Square wave pulse | / | 1.98 |
| Optimized ADRC | Unit step | 0 | 0.24 | Sinusoidal | / | 0.54 | Small disturbance | 0 | 0 | Big disturbance | 9.54 | 0.92 | Square wave pulse | / | 0.43 |
|
|