Research Article

Experimental Research and Simulation on the Mechanical Performance Degradation of Corroded Stud Shear Connectors

Table 2

Comparison between experimental and theoretical stud corrosion rate values.

Test numberNumber of testsCorrosion current density (mA/cm2)Corrosion time (h)Theoretical corrosion rate (%)Measured corrosion rate (%)

T-1500000
T-251.57755.660.88
T-351.510877.250.97
T-451.5154109.361.07
T-551.52321514.211.06
T-651.53092018.831.06