Research Article
Serviceability Assessment Method of Stay Cables with Vibration Control Using First-Passage Probability
Table 3
Numerical results of cable vibration (displacement) with/without vibration control on Cable C14.
| Wind cases | Standard deviation | Maximum displacement (m) | Un-controlled | Passive control (cd =1.5) | Control efficacy (%) | Un-controlled | Passive control (cd =1.5) | Control efficacy (%) |
| Case 1 (V10 = 12.89 m/s) | 6.45x10−3 | 3.32x10−3 | 48.53 | 2.71x10−2 | 1.38x10−2 | 49.01 | Case 2 (V10 = 20 m/s) | 1.72x10−2 | 9.21x10−3 | 46.45 | 7.10x10−2 | 3.82x10−2 | 46.20 | Case 3 (V10 = 36 m/s) | 2.82x10−2 | 1.64x10−2 | 41.84 | 1.17x10−1 | 8.41x10−2 | 28.12 |
|
|