Research Article

Numerical Study of Heat Transfer in Trefoil Buried Cable with Fluidized Thermal Backfill and Laying Parameter Optimization

Table 3

Computational results with different meshes.

GridRegionMinimum length of grid element [mm]Maximum length of grid element [mm]Total element number [K] [W]

Grid 1Zone 11.50.410228326.5668.899
Zone 21.50.4
Zone 31.50.5

Grid 2Zone 10.40.216337329.55769.892
Zone 21.50.4
Zone 31.50.4

Grid 3Zone 10.30.119346329.56368.903
Zone 20.30.1
Zone 30.40.2

Grid 4Zone 10.30.128394329.56368.903
Zone 20.30.1
Zone 30.350.15