Research Article
Numerical Study of Heat Transfer in Trefoil Buried Cable with Fluidized Thermal Backfill and Laying Parameter Optimization
Table 3
Computational results with different meshes.
| Grid | Region | Minimum length of grid element [mm] | Maximum length of grid element [mm] | Total element number | [K] | [W] |
| Grid 1 | Zone 1 | 1.5 | 0.4 | 10228 | 326.56 | 68.899 | Zone 2 | 1.5 | 0.4 | Zone 3 | 1.5 | 0.5 |
| Grid 2 | Zone 1 | 0.4 | 0.2 | 16337 | 329.557 | 69.892 | Zone 2 | 1.5 | 0.4 | Zone 3 | 1.5 | 0.4 |
| Grid 3 | Zone 1 | 0.3 | 0.1 | 19346 | 329.563 | 68.903 | Zone 2 | 0.3 | 0.1 | Zone 3 | 0.4 | 0.2 |
| Grid 4 | Zone 1 | 0.3 | 0.1 | 28394 | 329.563 | 68.903 | Zone 2 | 0.3 | 0.1 | Zone 3 | 0.35 | 0.15 |
|
|