Research Article
Numerical Study of Heat Transfer in Trefoil Buried Cable with Fluidized Thermal Backfill and Laying Parameter Optimization
Table 7
The comparison of
with RBNN and COMSOL (
= 1300 A).
| Samples | Design variables | [K] | [m] | [m] | [m] | RBNN | COMSOL |
| 1 | 0.3152 | 0.2035 | 0.3393 | 340.7534 | 340.095 | 2 | 0.1936 | 0.1294 | 0.5348 | 342.1368 | 342.075 | 3 | 0.3079 | 0.3779 | 0.4763 | 328.3667 | 330.314 | 4 | 0.3557 | 0.2250 | 0.5911 | 332.6455 | 332.348 | 5 | 0.2578 | 0.2849 | 0.5785 | 333.4514 | 332.856 | 6 | 0.2280 | 0.2790 | 0.4530 | 336.7406 | 336.332 | 7 | 0.3755 | 0.3126 | 0.4107 | 332.0261 | 332.229 | 8 | 0.1740 | 0.3672 | 0.6314 | 333.6398 | 331.612 | 9 | 0.1432 | 0.1645 | 0.6692 | 340.7285 | 339.486 | 10 | 0.1196 | 0.1443 | 0.3564 | 349.3775 | 350.652 |
|
|