Research Article

Mechanism and Modeling of Contaminant Accumulation on Hot-Film Air Flow Sensor

Table 8

Flow rate measured by No.6 and No.7 sensors.

Test time  
(h)
Reference value No.6 sensor No.7 sensor
(L/min)Flow rate  
(L/min)
Decrease amplitude of accuracy  
(%)
Flow rate  
(L/min)
Decrease amplitude of accuracy  
(%)

3001514.44%14.06.667%
6001513.97.333%13.311.333%
9001513.69.333%12.616%
12001513.212%11.920.667%