Research Article

Fault Detection of Insulators Using Second-order Fully Convolutional Network Model

Table 2

Segmentation accuracy (SA%) of three algorithms on six glass insulator images with different backgrounds in Figure 8.

Methods

CNN[31]0.99440.99390.99310.98300.99150.9886
FCN[34]0.98900.99120.99200.98900.99000.9886
SOFCN0.99870.99910.99760.99710.99760.9953