Parameters of model and Simulink configuration.

ParametersSymbolsValuesUnits

Transfer coefficientK20.944rad·s−1·V−1
Time constantT0.0158s
Reduction ratioi2
Lead of ball screwL0.005m
Target positionπ/3 (60)rad (deg)
Duration of erection processtf10s
Solver typeFixed-step