Some data of faulty fan on July 23, 2016.

Status parameterTime
0:38:020:40:140:46:180:55:461:01:421:05:161:16:221:21:081:32:341:40:22
Rotor speed (r/m)17.3816.979.361.2300000.210.14
Generator speed (r/m)1763.61702.81214.627.38.97.39.06.1953.41651.6
Temperature of bearing A (°C)43.842.644.047.748.548.447.146.745445.2
Temperature of bearing B (°C)45.145.846.244.548.847.346.445.546.847.1
Current of pitch motor 1 (A)12080000000040
Current of pitch motor 2 (A)705020000003020
Current of pitch motor 3 (A)504040000001050
Brake pressure (N)027.53110.14124.47160.29143.21120.45150.41140.12134.47
1 min average wind speed (m/s)8.329.9510.398.879.8110.3211.149.488.229.13
U1 phase winding current (A)890832326666644
U2 phase winding current (A)883838376666644
U3 phase winding current (A)880828356666644
Lubricant filter inlet pressure (N)−3.96−3.78−3.67−3.54−3.66−3.92−3.96−3.88−3.68−3.86
Lubricant filter outlet pressure (N)5.776.043.032.784.663.456.202.973.422.64
Pressure of main hydraulic system (N)143.12151.24160.14152.13130.24163.48153.46143.34132.04130.19
Wind angle (°)4.213.245.253.542.141.673.452.872.214.15
Grid voltage (kV)407.2406.4405.7407.2403.1401.8406.7405.3404.1405.9
Pitch angle 1 (°)0.250.3389.0489.0489.0489.0489.0489.0489.0489.04
Pitch angle 2 (°)0.270.3489.0289.0289.0289.0289.0289.0289.0289.02
Pitch angle 3 (°)0.270.3389.0489.0489.0489.0489.0489.0489.0489.04
Pitch controller location (°)56.2152.4700000000
Voltage of pitch capacitor (V)59.2359.1759.1059.1159.1459.1859.1759.2159.3359.12
Yaw speed (°/s)00.1200000000
Nacelle vibration (mm)0.060.040.010.010.010.020.020.010.020.03
Gearbox inlet oil temperature (°C)46.544.145.643.943.244.544.743.542.344.9
Generator torque deviation (N·m)56.6344.1223.1417.190.120.110000