Research Article

Study on Fuzzy Control for Air-To-Water Heat Pumps Connected to a Residential Floor Heating System

Table 1

Fuzzy control decision table.

to(o) − to(o-h)
NBNSZOPSPB

to(o)NBPBPBPBPMBPM
NSPMPMSPSZONS
ZOPSZONSNMSNM
PSNSNMSNMNMBNB
PBNMNMBNBNBNB