Research Article

Parameter Analysis of Wall Thickness of Cured-in-Place Pipe Linings for Semistructured Rehabilitation of Concrete Drainage Pipe

Figure 17

The relationship between CIPP wall thickness and (a) vertical displacement and CIPP wall thickness and (b) von Mises stress of CIPP for different traffic loads.
(a)
(b)