Research Article
Deep Forest-Based Fault Diagnosis Method for Chemical Process
Table 2
Faults details of the TE process.
| No. | Description | Type |
| 1 | A/C feed ratio, B composition constant (Stream 4) | Step | 2 | B composition, A/C ratio constant (Stream 4) | Step | 3 | D feed temperature (Stream 2) | Step | 4 | Reactor cooling water inlet temperature | Step | 5 | Condenser cooling water inlet temperature | Step | 6 | A feed loss (Stream 1) | Step | 7 | C header pressure loss–reduced availability (Stream 4) | Step | 8 | A, B, C feed composition (Stream 4) | Random variation | 9 | D feed temperature (Stream 2) | Random variation | 10 | C feed temperature (Stream 4) | Random variation | 11 | Reactor cooling water inlet temperature | Random variation | 12 | Condenser cooling water inlet temperature | Random variation | 13 | Reaction kinetics | Slow drift | 14 | Reactor cooling water valve | Sticking | 15 | Condenser cooling water valve | Sticking | 16 | Unknown | Unknown | 17 | Unknown | Unknown | 18 | Unknown | Unknown | 19 | Unknown | Unknown | 20 | Unknown | Unknown | 21 | The valve for Stream 4 was fixed at the steady state position | Constant position |
|
|