Research Article

Deep Forest-Based Fault Diagnosis Method for Chemical Process

Table 2

Faults details of the TE process.

No.DescriptionType

1A/C feed ratio, B composition constant (Stream 4)Step
2B composition, A/C ratio constant (Stream 4)Step
3D feed temperature (Stream 2)Step
4Reactor cooling water inlet temperatureStep
5Condenser cooling water inlet temperatureStep
6A feed loss (Stream 1)Step
7C header pressure loss–reduced availability (Stream 4)Step
8A, B, C feed composition (Stream 4)Random variation
9D feed temperature (Stream 2)Random variation
10C feed temperature (Stream 4)Random variation
11Reactor cooling water inlet temperatureRandom variation
12Condenser cooling water inlet temperatureRandom variation
13Reaction kineticsSlow drift
14Reactor cooling water valveSticking
15Condenser cooling water valveSticking
16UnknownUnknown