Research Article

Deep Forest-Based Fault Diagnosis Method for Chemical Process

Table 3

The testing average FDR and the training and testing time.

Window settingTesting average diagnostic accuracy (%)Training time (min)Testing time for one sample (ms)

[15, 30]56.342.10.7
[20, 45]68.738.30.5
[13, 30, 42]72.470.61.3
[18, 36, 45]75.661.51.1
[16, 27, 35, 42]74.879.71.4
[18, 25, 36, 47]75.983.41.6