Research Article

Optimization of Accelerated Destructive Degradation Testing of Cementitious Materials for Their Performances Qualification under Aggressive Environments: The Case of Carbonation

Table 11

Optimal solution under different two- or three-level scenarios.

StressSI1 (S1 = 300 Pa, S2 = 20,000 Pa, S3 = 40,000 Pa)SI2 (S1 = 30 Pa, S2 = 25,000 Pa, S3 = 50,000 Pa)SI3 (S1 = 30 Pa, , S3 = 50,000 Pa)

35 (59.3%)35 (59.3%)39 (66.1%)
6 (10.2%)6 (10.2%)
18 (30.5%)18 (30.5%)20 (33.9%)
111
11
214
573
22
232
Total duration5 months7 months8 months
7513
33
9610
Sample size595959
Cost109110991091
98.958.1115.7
Accuracy ε (%)28.222.430.4