Research Article

Optimization of Accelerated Destructive Degradation Testing of Cementitious Materials for Their Performances Qualification under Aggressive Environments: The Case of Carbonation

Table 9

Sample size under different upper bounds for .

Upper stress20,00025,00030,00035,00040,00045,00050,000

(102, 53)(99, 51)(97, 50)(95, 49)(94, 48)(93, 48)(92, 47)
N155150147144142141139